Basit öğe kaydını göster

dc.contributor.advisorErgün, Şule
dc.contributor.authorŞahin, Namık Kemal
dc.date.accessioned2019-10-21T11:54:38Z
dc.date.issued2019
dc.date.submitted2019-09-06
dc.identifier.citationAnonim, Nuclear Physics, Stability: the N-Z curve, https://a-levelphysicstutor.com/nucphys-NZ-curve.php (Erişim tarihi: 9 Temmuz 2019). Buckman, S. M., Ius, D., Digital coincidence counting, Nucl. Inst. Meth., A369, 368-374, 1996. International Commission on Radiation Units and Measurements (ICRU), Particle Counting in Radioactivity Measurements, ICRP Report 52, 1994. A Handbook of Radioactivity Measurements Procedures, National Vouncil on Radiation Protection and Measurements, NCRP Report No. 58, Bethesda, Maryland, 1985. Nichols, A. L., Nuclear decay data: Observations and reflections, Appl. Radiat. Isot., 64, 1384-1391, 2006. Baerg, A. P., Pressurized proportional counters for coincidence measurements. Nucl. Instr. Meth. 112, 95-99, 1973(a). Baerg, A. P., The efficiency extrapolation method in coincidence counting, Nucl. Instr. Meth., 112, 143-150, 1973(b). Baerg, A. P., Mutiple channel 4πβγ anti-coincidence counting, Nucl. Instr. and Methods, 190, 345, 1981. Bé, M.M., Coursol, N., Duchemin, B., Lagoutine, F., Legrand, J., Debertin, K. and Schönfeld, E., Table de radionucléides – introduction, Document CEA-ISBN 2-7272-0201-6, Commisariat à l’Énergie Atomique, France, 1999. Bé, M. M., Christe, V., Dulieu, C., Browne, E., Chechev, V., Kuzmanko, N., Helmer, R., Nichols, A., Schönfeld, A., Dersch, R., Table of radionuclides, vol. 1-A = 1 to 150, Monographie BIPM-5, Bureau International des Poids et Mesures, 2004a. Bé, M. M., Christe, V., Dulieu, C., Browne, E., Chechev, V., Kuzmanko, N., Helmer, R., Nichols, A., Schönfeld, A., Dersch, R., Table of radionuclides, vol. 1-A = 151 to 242, Monographie BIPM-5, Bureau International des Poids et Mesures, 2004b. Bé, M. M., Christe, V., Dulieu, C., Browne, Baglin, C., E., Chechev, V., Kuzmanko, N., Helmer, R., Kondev, F., MacMahon, D., Lee, K. B., Table of radionuclides, vol. 3-A = 3 to 244, Monographie BIPM-5, Bureau International des Poids et Mesures, 2006. Bobin, Ch. and Bouchard, J., A 4π(LS)β−γ coincidence system using a TDCR apparatus in the β-channel, Appl. Radiat. Isot. 64 (2006) 124. Bryant, J., Anticoincidence counting method for standardizing radioactive materials, Int. J. Appl. Radiat. Isot., 13 (1962) 273. Bryant, J., Advantage of anticoincidence counting for standardizing radionuclides emitting delayed gamam rays, Standardization of Radionuclides, p. 129, IAEA/STI/PUB/139, IAEA, Vienna, 1967. Buckman, S.M., Keightley, J.D., Smith, D. and Woods, M.J., The validation of a digital coincidence counting system, Appl. Radiat. Isot. 49, 1135-1140, 1998. Campion, P.J., The standardisation of radioisotopes by the beta-gamma coincidence method using high efficiency detectors, Int. J. Appl. Radiat. Isot. 4, 232-248, 1959. Campion, P.J., Taylor, J.G.V. and Merritt, J.S., The efficiency tracing technique for eliminating self-absorption errors in 4pb-counting. Int. J. Appl. Radiat. Isot. 8, 8-19, 1960. Cox, D.R. and Isham, V., A bivariate point process connected with electronic counters, Proc. Roy. Soc. Lond. A356, 149-160, 1977. Data sheet for BC-400, BC-404, BC-408, BC-412, BC-416 premium plastic scintillators, Saint-Gobain Ceramic & Plastics, Inc., 2018. Data sheet for 2005 scintillation preamplifier, Mirion Technologies, 2019. Dulieu, C., Christé, V. and Bé, M.M., A website dedicated to ionising radiation metrology. Appl. Radiat. Isot. 60, 133-137, 2004. Duran, M. T., Nedjadi, Y., Juget, F., Bochud, F., Bailat, C., Fast digital 4πβ - 4πγ coincidence counting with offline analysis at IRA, Appl. Radiat. Isot. 134, 329-336, 2018. Gandy, A., Mesure absolue de l’activité des radionuclides par le méthode descoïnc idences bêta-gamma à l’aide de détecteurs de grande efficacité - Etude des coïncidences instrumentales, Int. J. Appl. Radiat. Isot. 11, 75-91, 1961. Gandy, A., Mesure absolue de l’activité des radionuclides par le méthode des coïncidences bêta-gamma à l’aide de détecteurs de grande efficacité - Corrections de temps morts, Int. J. Appl. Radiat. Isot. 13, 501-513, 1962. Grigorescu, E.L., Sahagia, M., Razdolescu, A., Luca, A. and Radwan, R.M., Standardisation of 110mAg and 75Se by the beta-efficiency extrapolation method, Appl. Radiat. Isot. 49, 1165-1170, 1998. Photomultiplier tubes and related products, Hamamatsu Photonics K.K., Electron Tube Division, 2016. Havelka, M., Auerbach, P., Sochorova, J., Software coincidence counting, Appl. Radiat. Isot. 56 265-268, 2002. Havelka, M., Auerbach, P. and Sochorová, J., Standardisation of 54Mn and 65Zn using a software coincidence counting system, Appl. Radiat. Isot. 64 1215-1219, 2006. Havelka, M., and Sochorová, J., Standardisation of 124Sb and 152Eu using software coincidence counting system, Appl. Radiat. Isot. 68 1330-4, 2010. Hayward, R.W., On the determination of disintegration rates by the coincidence method using high efficiency detectors, Int. J. Appl. Radiat. Isot. 12 (1961) 148. Houtermans, H. And Miguel, M., 4π-β-γ coincidence counting for the calibration of nuclides with complex decay schemes, Int. J. Appl. Radiat. Isot., 13 (1962) 137. Hwang, H.Y, Park, T.S., Kim, K.H., Jeon, W.J., Oh, P.J., Lee, M.K., Han, K.H. and Yun, H.J., An improved method of correlation counting using a bi-dimensional data acquisition system, Nucl. Instr. and Meth. A369, 363-367, 1996a. Hwang, H.Y., Lee, C.B., Park, T.S. and Kim, H.J., A new method of isomer lifetime measurement, Nucl. Instrum. Meth. A383, 447-450, 1996b. Hwang, H.Y., Park, T.S., Oh, P.J., Lee, J.M. and Lee, M.K., Measurement of accidental coincidences for higher activity sources, Nucl. Instrum. Meth. A425, 488-491, 1999. Hwang, H.Y., Park, T.S., Oh, P.J., Lee, J.M. and Han, K.H., Development of a three dimensional data acquisition method for standardisation of beta emitting radionuclides, Appl. Radiat. Isot. 52, 393-397, 2000. Hwang, H-Y, Sung, K.S., Lee, K.B., Lee, J.M. and Park, T.S., Standardization of radionuclide by β(LS)-γ coincidence counting using the geometry variation method, Appl. Radiat. Isot. 64, 1119-1123, 2006. Judge, S. M., Arnold, D., Chauvenet, B., Colle, R., De Felice, P., Garcia-torano, E., Watjen, U., 100 Years of radionuclide metrology, Applied Radiation and Isotopes, Volume 87, Pages 27-31, 2014. Karam, L., International Committee for Radionuclide Metrology (ICRM), https://physics.nist.gov/ICRM/index.html, 2018 (Erişim tarihi: 28.08.2019). Keightley, J.D., DCC data format; Report DCC/DCCDataFormat/01, National Physical Laboratory, Teddington, UK, 2002. Keightley, J.D., Data Simulation for the validation of 4πβ−γ digital coincidence counting analysis software, Report GE/R/IM/11/05, Institute for Reference Materials and Measurements, Geel, Belgium, 2005. Keightley, J.D., DCC_SIM: A simulation routine for the validation of 4πβ−γ digital coincidence counting software. Chapter 17 in “Applied Modeling and computations in nuclear science”., ACS Symposium Series 945, American Chemical Society, Washington, DC, USA, 2006. Keightley, J. D., On the Development and Validation of a Digital Coincidence Counting System for the Primary Standardization of Radionuclides, Doktora Tezi, University of London, Londra, 2008. Keightley, J.D. and Watt, G.C., Digital Coincidence Counting (DCC) and its use in the corrections for out-of-channel gamma events in 4πβ−γ Coincidence Counting, Appl. Radiat. Isot. 56, 205-210, 2002. Knoll, G. F., Radiation Detection and Measurement, Third Edition, John Wiley & Sons, Inc., USA, 2000. Koskinas, M.F. and Dias, M., A coincidence system for radionuclide standardization using surface barrier detectors. Nucl. Inst. Meth. A280, 327-331, 2004. Kossert, K., Marganiec-Galazka, J., Mougeot, X., Nahle, O. J., Activity determination of 60Co and the importance of its beta spectrum, Appl. Radiat. Isot. Volume 134, P. 212-218, 2018. MacDonald, L., Counting Statistics and Error Propagation, Nuclear Medicine Physics Lectures, Imaging Research Lab., Radiology Dept., 2011. Müller, J. W., Counting statistics of a Poisson process with dead time, Report BIPM-111, Bureau International des Poids et Mesures, Sevres, France, 1970. Müller, J. W., Sur la perte de coincidences vraies par un temps mort cumulatif, Rapport BIPM-77/2, 4 p., 1977(b). NaI sintilasyon dedektörü özellikleri, 2018. Nedjadi, Y., Elektronik posta yoluyla özel yazışma, Mart 2019. Nedjadi, Y., Bailat, C., Bochud, F., Primary activity measurements with a 4πβ - 4πγ coincidence counting system, Appl. Radiat. Isot. 70, 249-256, 2012. Nelson, W. R., Hirayama, H. and Rogers, D. W. O., EGS4 code system, Techical Report SLAC-265, Stanford Linear Accelerator Center, CA, USA, 1985. Park T.S, Oh P.J, Lee M.K, Kim K.H, Jeon W.J., Ungyong Mulli 8(3) 311-316 (in Korean), 1995. Parzen, E., Stochastic Processes, Section 4.1, San Francisco, 1962. Photomultiplier tube series 9390B data sheet, ET Enterprises Limited, DS_9390B Issue 10, 2014. Pomme, S., Fitzgerald, R., and Keightley, J., Uncertainty of nuclear counting, Metrologia, 52, S3-17, 2015. Recommended data, Laboratorie National Henri Becquerel, http\\: nucleide.org/DDEP_WG/DDEPdata.htm, (Erişim tarihi: 19 Temmuz 2019). Sahagia, M., Ivan,C., Grigorescu, E.L., Campogni, M., de Felice, P. and Fazio, A., Standardisation of 65Zn by 4πβ−γ coincidence counting method with efficiency extrapolation, Appl. Radiat. Isot. 60, 423-427, 2004. Schönfeld, E., Janssen, H., Precise measurement of dead time, Nucl. Instr. Methods, A339, pp. 137-143, 1994. Simpson, B.R.S. and Meyer, B.R., Standardization and half-life of 201Tl by the 4π(x,e)-γ coincidence method with liquid scintillation counting in the 4π-channel, Appl. Radiat. Isot. 45, 669-673, 1994. Smith, D., Improved correction formulae for coincidence counting, Nucl. Inst. and Methods, 152, 505-519, 1978. Smith, D., Some developments in the Cox-Isham theory of coincidence corrections, including the extension to the computer-discrimination method, Appl. Radiat. Isot. 38, 813-821, 1987. Unno, Y., Sanami, T., Sasaki, S., Hagiwara, M., Yunoki, A., Evaluation of absolute measurement using a 4π plastic scintillator for the 4πβ-γ coincidence counting method, Appl. Radiat. Isot. 134, 302-306, 2018. User manual for DT5730-DT5725 digitizers, CAEN Electronic Instrumentation, 2016. User manual UM5960 for CoMPASS multiparametric DAQ software, CAEN Electronic Instrumentation, 2018. Williams, A., Campin, P. J., On the relative time distribution of pulses in the 4πβ-γ coincidence technique, Int. J. Appl. Radiat. Isot. 16, 555, 1965.tr_TR
dc.identifier.urihttp://hdl.handle.net/11655/9286
dc.description.abstractThe methods of data acquiring and processing in the 4πβ-γ coincidence counting systems for radionuclide standardization have been employed by using analogue electronic modules for decades. Since the supply and maintenance of these modules are costly, the need for the digital data acquiring and processing systems which are faster, more flexible and more reliable have been arised in parallel to the new advancements in radiation measurement systems. Achieving the signal parameters from the detector of a 4πβ-γ coincidence counting system by using a digital card and analyzing these signal parameters offline by using computer programs became an easy and innovative alternative method for the conventional analogue systems. In this thesis, a unique software has been developed to be used as data analysis method of the 4πβ-γ coincidence counting system setup in the Radionuclide Metrology Laboratories of Turkish Atomic Energy Authority (TAEK) for absolute activity standardization. This real-time coincidence counting software includes coincidence and anticoincidence methods. Activity calculations have been performed using unique algorithms of these methods. The validation of the software were done by determining the activity values of the standart radioactive solutions including 60Co, 133Ba, 152Eu and 166mHo radionuclides separately. Some amount of radioactive solutions were used as the source and then measured in the 4πβ-γ coincidence counting system. The data achieved from the counting system were analyzed in the software. The activity values of 60Co and 133Ba, which have relatively simple decay schemes, and of 152Eu ve 166mHo, which have relatively much more complicated decay schemes, have been determined by both coincidence and anticoincidence methods in a good agreement. The relative bias values between the two methods are found as 0.3% for 60Co, 0.18% for 133Ba, 0.1% for 152Eu and 0.08% for 166mHo. In addition, the Monte Carlo simulation of the 4πβ-γ coincidence counting system was performed, and the response functions of NaI detector for 60Co, 133Ba, 152Eu and 166mHo are determined as the detector efficiencies. The efficiency values and the experimental count rates of 60Co, 133Ba, 152Eu and 166mHo are used to calculate the activities of these radionuclides. When the activity values of these radionuclides determined by the coincidence method, anticoincidence method and Monte Carlo method were compared, it is found that the results agree well with each other within at most 2.5% relative bias. The developed digital coincidence software is now ready to be applied to the measurements of all radionuclides having simple or complicated decay schemes in the 4πβ-γ coincidence counting system. This primary radioactivity measurement system, which is used in world’s leading radioactivity measurement laboratories, has become availbale in TAEK Radionuclide Metrology Laboratories as a result of this thesis study.tr_TR
dc.description.tableofcontentsÖZET i ABSTRACT iii TEŞEKKÜR vi İÇİNDEKİLER vii ÇİZELGELER x ŞEKİLLER xv SİMGELER VE KISALTMALAR xix 1. GİRİŞ 1 2. GENEL BİLGİLER VE LİTERATÜR ÖZETİ 4 2.1. Nükleer Bozunmanın Kısa Özeti 4 2.2. Aktivite Ölçümünde Birincil Yöntemler 11 2.2.1. 4πβ-γ Çakışma Sayım Yöntemi 12 2.2.2. Aktivite Ölçümünde Önemli Parametreler 15 2.2.2.1. Ölü Zaman 15 3. ÇAKIŞMA SAYIM YÖNTEMİ 20 3.1. 4πβ-γ Çakışma Sayım Yönteminde Verim Dışadeğerleme 20 3.2. Çakışmalı Yöntemde Sayım Hızlarına Uygulanan Düzeltmeler 26 3.2.1. Tek Kanallara Uygulanan Düzeltmeler 26 3.2.2. Çakışma Kanalına Uygulanan Uzamayan Ölü Zaman Düzeltmeleri 29 3.2.2.1. Campion’un Yaklaşımı 30 3.2.2.2. Hayward’ın Yaklaşımı 31 3.2.2.3. Gandy’nin Yaklaşımı 32 3.2.2.4. Campion, Hayward ve Gandy Tarafından Geliştirilen Yaklaşımların Değerlendirilmesi 33 3.2.2.5. Cox-Isham ve Smith Uzamayan Ölü-Zaman Düzeltmesi 33 3.2.3. Çakışma Kanalına Uygulanan Uzayan Ölü-Zaman Düzeltmesi 35 3.3. 4πβ-γ Çakışma Yönteminin Diğer Türevleri 36 3.3.1. Çakışmasız Yöntem 36 3.3.1.1. Sayım Hızlarına Uygulanan Düzeltmeler 38 4. SAYIM SİSTEMİ ve MONTE CARLO SİMÜLASYONLARI 40 4.1. Sayım Sistemi ve Geometri 40 4.2. Kaynakların Hazırlanması 43 4.3. Monte-Carlo Simülasyonları ile Sistemin Optimizasyonu 45 5. DİJİTAL ÇAKIŞMA SAYIMI YAZILIMI ve UYGULAMASI 51 5.1. Dijital Çakışma Sayımı Veri Analiz Yazılımına Genel Bakış 51 5.2. Çakışmalı Yöntemin Program Modülleri 53 5.2.1. Ham Verinin Derlenmesi 53 5.2.2. Enerji Spektrumlarının Oluşturulması 54 5.2.3. Sinyal Gecikmesinin Belirlenmesi 54 5.2.4. Enerjinin Filtrelemesi 55 5.2.5. Ölü Zaman Uygulanması 56 5.2.6. Sinyal Zaman Aralıklarının Belirlenmesi 57 5.2.7. Çakışma Yapan Sinyallerin Belirlenmesi 57 5.2.8. Aktivitenin Belirlenmesi 58 5.2.9. Verim Dışadeğerleme Yöntemi 59 5.3. Çakışmasız Yöntemin Program Modülleri 60 5.3.1. Çakışma Yapmayan Sinyallerin Belirlenmesi 60 5.3.2. Çakışmasız Yöntem ile Aktivite Hesabı 62 5.4. Yazılımın Özeti 63 6. AKTİVİTE ÖLÇÜMLERİ VE SONUÇLAR 66 6.1. Monte Carlo Modellemelerinin Sonuçları 66 6.1.1. Elektron – Plastik Sintilatör Etkileşimleri 66 6.1.2. Gama Işını – NaI Etkileşimleri 68 6.2. Çakışmalı Yöntem ile Elde Edilen Sonuçlar 73 6.2.1. 60Co Ölçümünün Sonuçları 73 6.2.2. 133Ba Ölçümünün Sonuçları 94 6.2.3. 152Eu Ölçümünün Sonuçları 104 6.2.4. 166mHo Ölçümünün Sonuçları 118 6.2.5. Belirsizlik Hesaplamaları 127 6.3. Çakışmasız Yöntem ile Elde Edilen Sonuçlar 132 6.3.1. 60Co Ölçümünün Sonuçları 132 6.3.2. 133Ba Ölçümünün Sonuçları 138 6.3.3. 152Eu Ölçümünün Sonuçları 144 6.3.4. 166mHo Ölçümünün Sonuçları 152 6.3.5. Belirsizlik Hesaplamaları 158 6.4. Farklı Yöntemler ile Bulunan Sonuçların Karşılaştırılması 162 7. SONUÇ ve DEĞERLENDİRME 163 8. KAYNAKLAR 165 EKLER 170 Ek 1. 152Eu radyonüklitine ait bozunma şeması (Nucleide, 2019) 170 Ek 2. 166mHo radyonüklitine ait bozunma şeması (Nucleide, 2019) 176 Ek 3. LINEST Fonksiyonu ve Belirsizlik Hesaplama Yöntemi 178 Ek 4. Sayım İstatistiğinin Belirsizliğini Hesaplama 178 Ek 5. Toplam Belirsizlik Hesaplama 179 ÖZGEÇMİŞ 180tr_TR
dc.language.isoturtr_TR
dc.publisherFen Bilimleri Enstitüsütr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.subjectDijital çakışma sayımıtr_TR
dc.subject4πβ-γtr_TR
dc.subjectÇakışmalı yöntemtr_TR
dc.subjectÇakışmasız yöntemtr_TR
dc.subjectVerim dışadeğerleme yöntemitr_TR
dc.subjectMutlak radyoaktivite ölçümütr_TR
dc.titleDijital Çakışma Sayım Yönteminin Geliştirilmesi ve 4pi-Beta-Gama Sayım Sisteminde Karmaşık Bozunma Şemalı Belirli Radyoizotoplara Uygulanmasıtr_TR
dc.title.alternativeDevelopment Of Digital Coincidence Counting Method And Its Application In 4pı-Beta-Gamma Counting System On Certain Radioisotopes Having Complex Decay Schemetr_eng
dc.typeinfo:eu-repo/semantics/doctoralThesistr_TR
dc.description.ozetRadyonüklit standardizasyonu için 4πβ-γ çakışma sayım sistemlerinde veri alma ve işleme yöntemleri uzun yıllar analog elektronik modüller kullanılarak yapılmıştır. Bu modüllerin teminlerinin ve bakımlarının pahalı olması, radyasyon ölçüm sistemlerindeki gelişmelere paralel olarak geleneksel sistemlere alternatif daha hızlı, esnek ve güvenli olan dijital veri alma ve işleme ihtiyacını doğurmuştur. 4πβ-γ çakışma sayım sisteminde bulunan bir dedektörden sinyal zamanını ve sinyale ait diğer bilgileri dijital kartlar kullanarak elde etmek ve bu bilgileri yazılımlar vasıtasıyla çevrimdışı bir şekilde analiz etmek, geleneksel geleneksel sistemlere kıyasla daha kolay ve yenilikçi bir yöntem olmuştur. Bu tez çalışmasında, Radyasyon ve Hızlandırıcı Teknolojileri Dairesi Başkanlığı Radyonüklit Metrolojisi Laboratuvarlarında kurulumu yapılmış olan 4πβ-γ dijital çakışma sayım sisteminde veri analiz yöntemi olarak kullanılmak üzere özgün bir yazılım geliştirilmiştir. Bu gerçek zamanlı dijital çakışma yazılımı, beta-gama çakışmalı analiz yöntemini ve çakışmasız analiz yöntemini içermektedir. Özgün algoritmalar kullanılarak bu iki yöntemle aktivite hesaplamaları yapılmıştır. Yazılımın doğruluğu 60Co, 133Ba, 152Eu ve 166mHo radyonüklitlerini ayrı ayrı içeren ve aktivitesi bilinen radyoaktif standart çözeltilerden belli miktarlarda alınarak ve sistemde ölçümleri gerçekleştirilerek yapılmıştır. Çakışmalı yöntemde ve çakışmasız yöntemde, basit bozunma şemalı 60Co ve 133Ba için ve nispeten daha karmaşık bozunma şemalı 152Eu ve 166mHo için elde edilen aktivite değerlerinin birbirleriyle uyumlu olduğu görülmüştür. İki yöntem arasında 60Co için %0,3, 133Ba için %0,18, 152Eu için %0,1, 166mHo için ise %0,08 fark bulunmuştur. Ayrıca, Monte Carlo yöntemi kullanılarak 4πβ-γ çakışma sayım sisteminde dedektör-kaynak etkileşimleri simüle edilerek NaI dedektörünün 60Co, 133Ba, 152Eu ve 166mHo için gama tepki fonksiyonları elde edilmiş ve dedektör verimleri hesaplanmıştır. Bu verim değerleri ve deneysel olarak elde edilen gama sayım hızları kullanılarak 60Co, 133Ba, 152Eu ve 166mHo aktiviteleri hesaplanmıştır. Çakışmalı yöntem, çakışmasız yöntem ve Monte Carlo yöntemi kullanılarak hesaplanan aktivite değerleri karşılaştırıldığında, çakışmalı yöntem ile çakışmasız yöntem kullanılarak elde edilen sonuçlar arasında en fazla %0,3 göreceli fark bulunurken, çakışmalı yöntem ile Monte Carlo yöntemi arasında ise en fazla %2,5 göreceli fark olduğu görülmüştür. Bu tez çalışması çerçevesinde, özgün algoritmalar kullanılarak oluşturulan dijital çakışma yazılımı, laboratuvarda kurulu olan 4πβ-γ çakışma sayım sistemine hem basit hem de karmaşık bozunma şemalı radyonüklitler için uygulanmaya hazır durumdadır. Radyoaktivite ölçümü konusunda dünyanın önde gelen laboratuvarlarında bulunan bu birincil ölçüm yöntemi, bu tez çalışması sonucu TAEK Radyonüklit Metrolojisi Laboratuvarlarında da kullanılır duruma gelmiştir.tr_TR
dc.contributor.departmentNükleer Enerji Mühendisliğitr_TR
dc.embargo.termsAcik erisimtr_TR
dc.embargo.lift-
dc.fundingYoktr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster