CERRAHİ OLMAYAN PERİODONTAL TEDAVİDE ULTRASONİK SİSTEM (VECTOR® SYSTEM) VE MİNİMAL İNVAZİV EL ALETLERİYLE YAPILAN TEDAVİNİN SONUÇLARININ KARŞILAŞTIRILMASI ÜZERİNE RANDOMİZE TEK KÖR KLİNİK ÇALIŞMA
Abstract
Objective: Periodontitis is a chronic inflammatory disease characterized by the progressive destruction of the periodontal supporting tissues as a result of a dysregulated host response to dental biofilm. The treatment of intrabony periodontal defects represents a particular clinical challenge because of anatomical limitations. The aim of this randomized, single-blind, controlled clinical trial was to compare the clinical and radiographic effectiveness of the Vector® ultrasonic system and minimally invasive hand instruments in the non-surgical treatment of intrabony periodontal defects.
Materials and Methods: Individuals with Stage III–IV periodontitis and intrabony periodontal defects were included in the study. Patients were randomized into a test group treated with the Vector® system and a control group treated with Gracey Mini-Five curettes as minimally invasive hand instruments. A total of 44 defects were initially planned for inclusion; following losses during the follow-up period, the 6-month outcomes of 41 intrabony periodontal defects in 33 patients were evaluated. Clinical assessments included plaque index (PI), gingival index (GI), probing depth (PD), clinical attachment level (CAL), bleeding on probing (BOP), and periodontal pocket depth (PPD). Radiographic assessments included measurements of intrabony defect depth and defect angle.
Results: Both treatment methods resulted in significant improvements in clinical and radiographic parameters compared with baseline. However, at the end of 6 months, greater improvements were observed in the test group than in the control group in mean PPD, deepest PPD, PI, GI, and CAL values of the involved tooth (p<0.05). The reduction in radiographic defect depth from baseline to 6 months was significantly greater in the test group (p=0.004). In contrast, defect angle had no significant effect on treatment outcomes (p>0.05).
In the vertical defect sites treated in the test group, a greater number of sites achieved a probing depth of ≤3 mm after treatment, whereas fewer sites exhibited residual pockets of ≥5 mm and bleeding on probing. In addition, baseline deepest probing depth was positively correlated with probing depth reduction from baseline to 6 months (rₛ=0.432; p=0.005). Baseline radiographic defect depth was also positively correlated with the reduction in radiographic defect depth from baseline to 6 months (rₛ=0.517; p=0.001).
Conclusion: The 6-month results of the study demonstrate that both treatment approaches are effective in the non-surgical treatment of intrabony periodontal defects. Nevertheless, the Vector® system provided more favorable outcomes, particularly in terms of probing depth reduction, clinical attachment gain, and reduction in radiographic defect depth. These findings suggest that the Vector® system may be an effective alternative to minimally invasive hand instruments in the non-surgical treatment of intrabony periodontal defects.