Basit öğe kaydını göster

dc.contributor.authorAktemur Türker, Sevinç
dc.contributor.authorUzunoğlu, Emel
dc.contributor.authorYılmaz, Zeliha
dc.date.accessioned2019-12-16T06:34:44Z
dc.date.available2019-12-16T06:34:44Z
dc.date.issued2013
dc.identifier.issn2234-7658
dc.identifier.urihttps://doi.org/10.5395/rde.2013.38.4.234
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3843035/
dc.identifier.urihttp://hdl.handle.net/11655/19056
dc.description.abstractObjectives This study evaluated the effects of intraradicular moisture on the pushout bond strength of a fibre post luted with several self-adhesive resin cements. Materials and Methods Endodontically treated root canals were treated with one of three luting cements: (1) RelyX U100, (2) Clearfil SA, and (3) G-Cem. Roots were then divided into four subgroups according to the moisture condition tested: (I) dry: excess water removed with paper points followed by dehydration with 95% ethanol, (II) normal moisture: canals blot-dried with paper points until appearing dry, (III) moist: canals dried by low vacuum using a Luer adapter, and (IV) wet: canals remained totally flooded. Two 1-mm-thick slices were obtained from each root sample and bond strength was measured using a push-out test setup. The data were analysed using a two-way analysis of variance and the Bonferroni post hoc test with p = 0.05. Results Statistical analysis demonstrated that moisture levels had a significant effect on the bond strength of luting cements (p < 0.05), with the exception of G-Cem. RelyX U100 displayed the highest bond strength under moist conditions (III). Clearfil SA had the highest bond strength under normal moisture conditions (II). Statistical ranking of bond strength values was as follows: RelyX U100 > Clearfil SA > G-Cem. Conclusions The degree of residual moisture significantly affected the adhesion of luting cements to radicular dentine.
dc.relation.isversionof10.5395/rde.2013.38.4.234
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleEffects Of Dentin Moisture On The Push-Out Bond Strength Of A Fiber Post Luted With Different Self-Adhesive Resin Cements
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalRestorative Dentistry & Endodontics
dc.contributor.departmentEndodonti
dc.identifier.volume38
dc.identifier.issue4
dc.identifier.startpage234
dc.identifier.endpage240
dc.description.indexPubMed


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster