Show simple item record

dc.contributor.authorSalci, Yeliz
dc.contributor.authorKaranfil, Ecem
dc.contributor.authorBalkan, Ayla Fil
dc.contributor.authorKutukcu, Ebru Calik
dc.contributor.authorCeren, Ali Naim
dc.contributor.authorAyvat, Fatma
dc.contributor.authorBekircan-Kurt, Can Ebru
dc.contributor.authorArmutlu, Kadriye
dc.date.accessioned2021-06-08T06:09:49Z
dc.date.available2021-06-08T06:09:49Z
dc.date.issued2019
dc.identifier.issn0148-639X
dc.identifier.urihttp://dx.doi.org/10.1002/mus.26345
dc.identifier.urihttp://hdl.handle.net/11655/24683
dc.description.abstractIntroduction: We sought to evaluate the test-retest reliability and construct validity of the 6- and 2-minute walk tests (6mWT and 2mWT, respectively) in patients with myasthenia gravis (MG). Methods: Thirty-one patients with generalized MG were enrolled in this study. The 6mWT, 2mWT, MG-specific quality of life questionnaire Turkish version (MG-QoL15T), quantitative myasthenia gravis test (QMG), and pulmonary function tests were administered. Results: The intraclass correlation coefficients of 2mWT and 6mWT were 0.894 and 0.932, respectively. The 6mWT and 2mWT had moderate correlations with forced vital capacity, maximal inspiratory pressure, QMG score, and MG-QoL15T score (rho for 6mWT: 0.579, 0.539, -0.572, and -0.474; rho for 2mWT: 0.460, 0.446, -0.532, -0.457). Both tests had similar performances for predicting disease severity (area under the curve = 0.761 for 6mWT and 0.759 for 2mWT). Discussion: The 6mWT and 2mWT have excellent test-retest reliability as well as moderate construct validity for the evaluation of functional exercise capacity patients with MG. Muscle Nerve 59:208-212, 2019
dc.language.isoen
dc.relation.isversionof10.1002/mus.26345
dc.rightsAttribution 4.0 United States
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectvalidity
dc.subject2-minute walk test
dc.subject6-minute walk test
dc.subjectfunctional exercise capacity
dc.subjectmyasthenia gravis
dc.subjecttest-retest reliability
dc.titleFunctional Exercise Capacity Evaluated By Timed Walk Tests In Myasthenia Gravis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalMuscle & Nerve
dc.contributor.departmentFizyoterapi ve Rehabilitasyon
dc.identifier.volume59
dc.identifier.issue2
dc.description.indexWoS
dc.description.indexScopus


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution 4.0 United States
Except where otherwise noted, this item's license is described as Attribution 4.0 United States