Show simple item record

dc.contributor.authorKivanc, Huseyin
dc.contributor.authorGultekin, Melis
dc.contributor.authorGurkaynak, Murat
dc.contributor.authorOzyigit, Gokhan
dc.contributor.authorYildiz, Ferah
dc.date.accessioned2021-06-03T05:42:57Z
dc.date.available2021-06-03T05:42:57Z
dc.date.issued2019
dc.identifier.issn1526-9914
dc.identifier.urihttp://dx.doi.org/10.1002/acm2.12757
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909119/
dc.identifier.urihttp://hdl.handle.net/11655/24110
dc.description.abstractIntroduction The aim of this study was to compare five different techniques for chest wall (CW) and lymphatic irradiation in patients with left‐sided breast carcinoma. Methods Three‐dimensional conformal radiotherapy (3DCRT), forward‐planned intensity‐modulated radiotherapy (FP‐IMRT), inverse‐planned IMRT (IP‐IMRT; 7‐ or 9‐field), and hybrid IP‐/FP‐IMRT were compared in 10 patients. Clinical target volume (CTV) included CW and internal mammary (IM), supraclavicular (SC), and axillary nodes. Planning target volumes (PTVs), CTVs, and organs at risks (OARs) doses were analyzed with dose–volume histograms (DVHs). Results No differences could be observed among the techniques for doses received by 95% of the volume (D95%) of lymphatics. However, the FP‐IMRT resulted in a significantly lower D95% dose to the CW‐PTV compared to other techniques (P = 0.002). The 9‐field IP‐IMRT achieved the lowest volumes receiving higher doses (hotspots). Both IP‐IMRT techniques provided similar mean doses (Dmean) for the left lung which were smaller than the other techniques. There was no difference between the techniques for maximum dose (Dmax) of right breast. However, FP‐IMRT resulted in lower Dmean and volume of right breast receiving at least 5 Gy doses compared to other techniques. Conclusion The dose homogeneity in CW‐CTV was better using IMRT techniques compared to 3DCRT. Especially 9‐field IP‐IMRT provided a more homogeneous dose distribution in IM and axillary CTVs. Moreover, the OARs volumes receiving low radiation doses were larger with IP‐IMRT technique, while volumes receiving high radiation doses were larger with FP‐IMRT technique. Hybrid IMRT plans were found to have the advantages of both FP‐ and IP‐IMRT techniques.
dc.language.isoen
dc.relation.isversionof10.1002/acm2.12757
dc.rightsAttribution 4.0 United States
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleDosimetric Comparison Of Three‐Dimensional Conformal Radiotherapy And Intensity‐Modulated Radiotherapy For Left‐Sided Chest Wall And Lymphatic Irradiation
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalJournal Of Applied Clinical Medical Physics
dc.contributor.departmentRadyasyon Onkolojisi
dc.identifier.volume20
dc.identifier.issue12
dc.description.indexPubMed