Show simple item record

dc.contributor.authorArat, Anıl
dc.contributor.authorPoker, A
dc.contributor.authorÖcal, O
dc.contributor.authorÖztürk, E
dc.date.accessioned2021-04-14T06:07:35Z
dc.date.available2021-04-14T06:07:35Z
dc.date.issued2021-03-04
dc.identifier.citationPropensity Score Analysis of Flow Diverters Placed in Scaffolding Stents A. Poker, O. Öcal, E. Öztürk, A. Arat American Journal of Neuroradiology Mar 2021, DOI: 10.3174/ajnr.A7040tr_TR
dc.identifier.urihttp://dx.doi.org/10.3174/ajnr.A7040
dc.identifier.urihttp://www.ajnr.org/content/early/2021/03/04/ajnr.A7040
dc.identifier.urihttp://hdl.handle.net/11655/23644
dc.description.abstractAbstract Background and purpose: Flow-diverter deployment within a stent remains controversial, but flow-diverter deployment within a scaffolding stent has been performed occasionally. To date, an analysis of this scaffolding technique has not been reported. We aimed to evaluate whether the scaffolding technique adversely affects the outcomes of flow diversion. Materials and methods: Patients who had undergone intracranial aneurysm treatment using a Silk flow diverter with (scaffolding group) or without (bare flow-diverter group) a scaffolding stent were identified retrospectively and compared. Propensity score matching was used to match the aneurysms in both groups for variables with a significant difference between groups. Aneurysm occlusion rates and clinical outcomes were compared. Results: There were 84 patients (105 aneurysms) in the bare flow-diverter group and 21 patients (22 aneurysms) in the scaffolding group (using 20 LEO stents and 1 Enterprise stent). The aneurysms in the scaffolding group were larger (mean, 13.1 [SD, 10.7] versus 7 [SD, 4.5] mm, P = .001) and more likely to be fusiform (40.9% versus 5.7%, P < .001) than in the bare flow-diverter group. After 2:1 propensity score matching, 24 aneurysms in the bare flow-diverter group and 15 in the scaffolding group were matched. Aneurysm occlusion rates did not significantly differ between groups at 1-3 months (41.2 versus 33.3%, P > .99), 3-6 months (55.5 versus 75.0%, P = .44), 7-12 months (65.0 versus 90.0%, P = .21), or beyond 1 year (73.6 versus 91.6%, P = .36). There was no difference in complication rates between the groups (P > .99). Conclusions: Placement of a scaffolding stent before flow diversion does not adversely affect aneurysm occlusion or complication rates.tr_TR
dc.language.isoentr_TR
dc.publisherAmerican Society of Neuroradiologytr_TR
dc.relation.isversionof10.3174/ajnr.A7040tr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.rightsAttribution 4.0 United States
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectgirişimsel nöroradyolojitr_TR
dc.subjectScaffolding Stentstr_TR
dc.subject.lcshRadyoloji. Tanısal görüntülemetr_TR
dc.titlePropensity Score Analysis of Flow Diverters Placed in Scaffolding Stentstr_TR
dc.typeinfo:eu-repo/semantics/articletr_TR
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalAmerican Journal of Neuroradiologytr_TR
dc.contributor.departmentRadyolojitr_TR
dc.description.indexPubMedtr_TR
dc.fundingYoktr_TR


Files in this item

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess