Basit öğe kaydını göster

dc.contributor.authorYuruk, Emrah
dc.contributor.authorGureser, Gokhan
dc.contributor.authorTuken, Murat
dc.contributor.authorErtas, Kasim
dc.contributor.authorSerefoglu, Ege Can
dc.date.accessioned2020-01-16T13:12:19Z
dc.date.available2020-01-16T13:12:19Z
dc.date.issued2016
dc.identifier.issn2080-4806
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4986300/
dc.identifier.urihttps://doi.org/10.5173/ceju.2016.779
dc.identifier.urihttp://hdl.handle.net/11655/21725
dc.description.abstractIntroduction The aim of this study was to demonstrate the efficacy of Instadose™, a novel dosimeter designed for radiation workers to provide a measurement of the radiation dose at any time from any computer; to determine the amount of radiation exposure during percutaneous nephrolithotomy (PNL); and to evaluate the factors that affect the amount of radiation exposed. Material and methods Two experienced surgeons wore Instadose™ on the outer part of their lead aprons during the PNL procedures performed between December 2013 and July 2014. Patient demographics and stone characteristics were noted. Factors affecting radiation dose were determined. Fluoroscopic screening time was compared with the amount of radiation in order to validate the measurements of Instadose™. Results Overall, 51 patients with a mean age of 43.41 ±18.58 (range 1–75) years were enrolled. Male to female ratio was 35/16. The amount of radiation was greater than 0.01mSv in only 19 (37.25%) cases. Stone location complexity (p = 0.380), dilation type (p = 0.584), stone size (p = 0.565), dilation size (p = 0.891) and access number (p = 0.268) were not associated with increased radiation exposure. Instadose™ measurements were correlated with fluoroscopic screening time (r = 0.519, p = 0.001). Conclusions Instadose™ is a useful tool for the measurement of radiation exposure during PNL. The advantage of measuring the amount of radiation exposure after each PNL operation is that it may aid urologists in taking appropriate precautions to minimize the risk of radiation related complications.tr_TR
dc.language.isoentr_TR
dc.publisherPolish Urological Associationtr_TR
dc.relation.isversionof10.5173/ceju.2016.779tr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.subjectInternationaltr_TR
dc.subject.lcshKonu Başlıkları Listesi::Tıp::Boşaltım sistemitr_TR
dc.titleA Novel Dosimeter For Measuring The Amount Of Radiation Exposure Of Surgeons During Percutaneous Nephrolithotomy: Instadose™tr_TR
dc.typeinfo:eu-repo/semantics/articletr_TR
dc.relation.journalCentral European Journal of Urologytr_TR
dc.contributor.departmentEndüstri Mühendisliğitr_TR
dc.identifier.volume69tr_TR
dc.identifier.issue2tr_TR
dc.identifier.startpage198tr_TR
dc.identifier.endpage203tr_TR
dc.description.indexPubMedtr_TR
dc.fundingYoktr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster