dc.contributor.author | Machado Rodrigues, Fernanda | |
dc.contributor.author | Demeyer, Heleen | |
dc.contributor.author | Hornikx, Miek | |
dc.contributor.author | Camillo, Carlos Augusto | |
dc.contributor.author | Calik-Kutukcu, Ebru | |
dc.contributor.author | Burtin, Chris | |
dc.contributor.author | Janssens, Wim | |
dc.contributor.author | Troosters, Thierry | |
dc.contributor.author | Osadnik, Christian | |
dc.date.accessioned | 2019-12-19T07:02:52Z | |
dc.date.available | 2019-12-19T07:02:52Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 1479-9723 | |
dc.identifier.uri | https://doi.org/10.1177/1479972316687210 | |
dc.identifier.uri | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720235/ | |
dc.identifier.uri | http://hdl.handle.net/11655/20879 | |
dc.description.abstract | This study investigated the validity and reliability of fixed strain gauge measurements of isometric quadriceps force in patients with chronic obstructive pulmonary disease (COPD). A total cohort of 138 patients with COPD were assessed. To determine validity, maximal volitional quadriceps force was evaluated during isometric maximal voluntary contraction (MVC) manoeuvre via a fixed strain gauge dynamometer and compared to (a) potentiated non-volitional quadriceps force obtained via magnetic stimulation of the femoral nerve (twitch (Tw); n = 92) and (b) volitional computerized dynamometry (Biodex; n = 46) and analysed via correlation coefficients. Test–retest and absolute reliability were determined via calculations of intra-class correlation coefficients (ICCs), smallest real differences (SRDs) and standard errors of measurement (SEMs). For this, MVC recordings in each device were performed across two test sessions separated by a period of 7 days (n = 46). Strain gauge measures of MVC demonstrated very large correlation with Tw and Biodex results (r = 0.86 and 0.88, respectively, both p < 0.0001). ICC, SEM and SRD were numerically comparable between strain gauge and Biodex devices (ICC = 0.96 vs. 0.93; SEM = 8.50 vs. 10.54 N·m and SRD = 23.59 vs. 29.22 N·m, respectively). The results support that strain gauge measures of quadriceps force are valid and reliable in patients with COPD. | |
dc.language.iso | en | |
dc.relation.isversionof | 10.1177/1479972316687210 | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.title | Validity And Reliability Of Strain Gauge Measurement Of Volitional Quadriceps Force In Patients With Copd | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.relation.journal | Chronic Respiratory Disease | |
dc.contributor.department | Fizyoterapi ve Rehabilitasyon | |
dc.identifier.volume | 14 | |
dc.identifier.issue | 3 | |
dc.identifier.startpage | 289 | |
dc.identifier.endpage | 297 | |
dc.description.index | PubMed | |
dc.description.index | WoS | |
dc.description.index | Scopus | |