Basit öğe kaydını göster

dc.contributor.authorMachado Rodrigues, Fernanda
dc.contributor.authorDemeyer, Heleen
dc.contributor.authorHornikx, Miek
dc.contributor.authorCamillo, Carlos Augusto
dc.contributor.authorCalik-Kutukcu, Ebru
dc.contributor.authorBurtin, Chris
dc.contributor.authorJanssens, Wim
dc.contributor.authorTroosters, Thierry
dc.contributor.authorOsadnik, Christian
dc.date.accessioned2019-12-19T07:02:52Z
dc.date.available2019-12-19T07:02:52Z
dc.date.issued2017
dc.identifier.issn1479-9723
dc.identifier.urihttps://doi.org/10.1177/1479972316687210
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720235/
dc.identifier.urihttp://hdl.handle.net/11655/20879
dc.description.abstractThis study investigated the validity and reliability of fixed strain gauge measurements of isometric quadriceps force in patients with chronic obstructive pulmonary disease (COPD). A total cohort of 138 patients with COPD were assessed. To determine validity, maximal volitional quadriceps force was evaluated during isometric maximal voluntary contraction (MVC) manoeuvre via a fixed strain gauge dynamometer and compared to (a) potentiated non-volitional quadriceps force obtained via magnetic stimulation of the femoral nerve (twitch (Tw); n = 92) and (b) volitional computerized dynamometry (Biodex; n = 46) and analysed via correlation coefficients. Test–retest and absolute reliability were determined via calculations of intra-class correlation coefficients (ICCs), smallest real differences (SRDs) and standard errors of measurement (SEMs). For this, MVC recordings in each device were performed across two test sessions separated by a period of 7 days (n = 46). Strain gauge measures of MVC demonstrated very large correlation with Tw and Biodex results (r = 0.86 and 0.88, respectively, both p < 0.0001). ICC, SEM and SRD were numerically comparable between strain gauge and Biodex devices (ICC = 0.96 vs. 0.93; SEM = 8.50 vs. 10.54 N·m and SRD = 23.59 vs. 29.22 N·m, respectively). The results support that strain gauge measures of quadriceps force are valid and reliable in patients with COPD.
dc.language.isoen
dc.relation.isversionof10.1177/1479972316687210
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleValidity And Reliability Of Strain Gauge Measurement Of Volitional Quadriceps Force In Patients With Copd
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalChronic Respiratory Disease
dc.contributor.departmentFizyoterapi ve Rehabilitasyon
dc.identifier.volume14
dc.identifier.issue3
dc.identifier.startpage289
dc.identifier.endpage297
dc.description.indexPubMed
dc.description.indexWoS
dc.description.indexScopus


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster