Basit öğe kaydını göster

dc.contributor.authorUcar, Fatma
dc.contributor.authorErden, Gonul
dc.contributor.authorTaslipinar, Mine Yavuz
dc.contributor.authorOzturk, Gulfer
dc.contributor.authorGinis, Zeynep
dc.contributor.authorBulut, Erdem
dc.contributor.authorDelibas, Namik
dc.date.accessioned2019-12-16T10:29:21Z
dc.date.available2019-12-16T10:29:21Z
dc.date.issued2016
dc.identifier.issn1452-8258
dc.identifier.urihttps://doi.org/10.1515/jomb-2015-0012
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5346795/
dc.identifier.urihttp://hdl.handle.net/11655/20101
dc.description.abstractBackground Sample classification and registration have been recognized as important and time-consuming processes in laboratories. There is increasing pressure on laboratories to automate processes due to intense workload and reduce manual procedures and errors. The aim of the present study was to evaluate the positive effects of an automatic tube registration and sorting system on specimen processing. Methods An automatic tube registration and sorting system (HCTS2000 MK2, m-u-t AG, Wedel, Germany) was evaluated. Turnaround time (TAT), rate of sample rejection and unrealized tests were examined 12 months pre- and post-implementation of the automatic tube sorting and registration system. Results The mean TAT of routine chemistry immunoassay, complete blood cell count (CBC) and coagulation samples were significantly improved (P<0.001). The number of rejected samples and unrealized tests was insignificantly decreased post-implementation of the system (0.4% to 0.2% and 4.5% to 1.4%, respectively) (P>0.05). Conclusions By reducing delays and errors in the preanalytical processing and sorting of samples, significant improvements in specimen processing were observed after implementation of the system. These results suggest that an automatic tube registration and sorting system may also be used to improve specimen processing in a higher-volume core laboratory.
dc.relation.isversionof10.1515/jomb-2015-0012
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleGreater Efficiency Observed 12 Months Post-Implementation Of An Automatic Tube Sorting And Registration System In A Core Laboratory
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalJournal of Medical Biochemistry
dc.contributor.departmentBiyokimya
dc.identifier.volume35
dc.identifier.issue1
dc.identifier.startpage6-Jan
dc.description.indexPubMed
dc.description.indexWoS
dc.description.indexScopus


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster