Basit öğe kaydını göster

dc.contributor.authorKoc-Vural, Uzay
dc.contributor.authorBaltacioglu, Ismail
dc.contributor.authorAltinci, Pinar
dc.date.accessioned2019-12-16T07:18:09Z
dc.date.available2019-12-16T07:18:09Z
dc.date.issued2017
dc.identifier.issn2234-7658
dc.identifier.urihttps://doi.org/10.5395/rde.2017.42.2.118
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426223/
dc.identifier.urihttp://hdl.handle.net/11655/19254
dc.description.abstractObjectives This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods Disk-shaped specimens (8 mm in diameter and 4 mm in thickness) were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent), one micro-hybrid bulk-fill (Quixfil, Dentsply), and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr) resin-based composites, and aged by thermocycling (between 5 - 55℃, 3,000 cycles). Then, they were divided into subgroups according to the polishing procedure as SwissFlex (Coltène/Whaledent), Optidisc (Kerr), and Praxis TDV (TDV Dental) (n = 12 per subgroup). One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at 37℃. The color differences (ΔE) were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (α = 0.05). Results Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p < 0.05). Significant color changes were detected after 1 day storage in coffee solution (p < 0.05), except Quixfil/Optidisc which was color-stable after 7 days (p > 0.05). Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05). Conclusions Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.
dc.relation.isversionof10.5395/rde.2017.42.2.118
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleColor Stability Of Bulk-Fill And Incremental-Fill Resin-Based Composites Polished With Aluminum-Oxide Impregnated Disks
dc.typeinfo:eu-repo/semantics/article
dc.relation.journalRestorative Dentistry & Endodontics
dc.contributor.departmentRestoratif Diş Tedavisi
dc.identifier.volume42
dc.identifier.issue2
dc.identifier.startpage118
dc.identifier.endpage124
dc.description.indexPubMed


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster