Show simple item record

dc.contributor.authorKarcaaltincaba, Musturay
dc.contributor.authorIdilman, Ilkay
dc.contributor.authorCelik, Azim
dc.date.accessioned2019-12-10T11:31:26Z
dc.date.available2019-12-10T11:31:26Z
dc.date.issued2011
dc.identifier.issn1305-3825
dc.identifier.urihttps://doi.org/10.4261/1305-3825.DIR.4134-10.1
dc.identifier.urihttp://hdl.handle.net/11655/15904
dc.description.abstractPURPOSE To demonstrate magnetic resonance imaging (MRI) findings of the focal sparing of iron and fat in liver tissue in patients with hepatic iron overload. MATERIALS AND METHODS We retrospectively reviewed 48 liver MRI's performed in patients with hemosiderosis from 2007-2009. We selected five (10%) of these patients based on the observation of focal signal abnormalities in the posterior aspect of segment 4, anterior to the portal vein, on in- and out-of-phase T1-weighted gradient-echo images. To further characterize this signal abnormality in segment 4, we calculated the simultaneous proton density tat fraction and R2* relaxometry using the investigational version of a quantitative chemical shift-based water-fat separation method known as IDEAL-IQ with a multi-echo gradient echo sequence. Visual assessment and objective measurements were performed for the focal sparing of iron and fat. RESULTS The diagnoses of the five patients included thalassemia (n=3), aplastic anemia (n=1), and myelodosysplastic syndrome (n=1). The focal sparing of iron was hypointense on R2* relaxometry compared to the rest of the liver. Fat fraction images failed to demonstrate a heterogeneous fat distribution. The focal sparing of fat in the liver with iron overload appeared as a reduced fat-containing area (fat fraction, 4%) in segment 4 compared to the remainder of the left lobe (fat fraction, 12%). The R2* map revealed no difference between the focal fat-sparing area and the rest of the liver. Areas in which focal fat and iron sparing occurred were not visible on post-contrast and diffusion-weighted images. CONCLUSION Focal fat and iron sparing in patients with liver siderosis can mimic a lesion. Quantitative MRI techniques can help to characterize abnormal signal changes in segment 4 of the liver in patients with hepatic iron overload and can eliminate the need for biopsy of pseudolesions.
dc.language.isoen
dc.publisherTurkish Soc Radiology
dc.relation.isversionof10.4261/1305-3825.DIR.4134-10.1
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectRadiology, Nuclear Medicine & Medical Imaging
dc.titleFocal Sparing Of Iron And Fat In Liver Tissue In Patients With Hemosiderosis: Diagnosis With Combination Of R2*Relaxometry And Proton Density Fat Fraction Calculation By Mri
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalDiagnostic And Interventional Radiology
dc.contributor.departmentRadyoloji
dc.identifier.volume17
dc.identifier.issue4
dc.identifier.startpage323
dc.identifier.endpage327
dc.description.indexWoS
dc.description.indexScopus