Show simple item record

dc.contributor.authorDeniz, Ali
dc.contributor.authorSahiner, Levent
dc.contributor.authorAytemir, Kudret
dc.contributor.authorKaya, Bans
dc.contributor.authorKabakci, Giray
dc.contributor.authorLe Tokgozoglu, La
dc.contributor.authorOto, Ali
dc.date.accessioned2019-12-10T11:24:08Z
dc.date.available2019-12-10T11:24:08Z
dc.date.issued2012
dc.identifier.issn1897-5593
dc.identifier.urihttps://doi.org/10.5603/CJ.2012.0089
dc.identifier.urihttp://hdl.handle.net/11655/15623
dc.description.abstractBackground: The main purpose of this study is to determine the correlation of inter- and intraatrial conduction times between the electrophysiological and tissue Doppler echocardiographic measurements, and to evaluate the appropriateness of tissue Doppler echocardiography for this measurement. Methods: One-hundred and one patients were included in the study who underwent electrophysiological study for clinical arrhythmias. Inter- and intraatrial conduction times were measured from intracardiac electrograms. Atrial conduction times were also measured by tissue Doppler echocardiography by evaluating atrial electromechanical delay between lateral mitral annulus, septal mitral annulus, and right ventricular tricuspid annulus. The correlation between electrophysiological and echocardiographic atrial conduction times were analyzed. Results: We found a weak correlation between the measurements of interatrial conduction times with the electrophysiological and tissue Doppler techniques (r = 0.308; p = 0.002). The correlation for intraleft atrial conduction times was moderate (r = 0.652; p < 0.001). There was no correlation between the measurements of intra-right atrial conduction times. Conclusions: We concluded that tissue Doppler echocardiography can be used for the measurement of interatrial and intra-left atrial conduction times. Tissue Doppler echocardiography can be a suitable technique to evaluate atrial substrate. (Cardiol J 2012; 19,5: 487-493)
dc.language.isoen
dc.publisherVia Medica
dc.relation.isversionof10.5603/CJ.2012.0089
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCardiovascular System & Cardiology
dc.titleTissue Doppler Echocardiography Can Be A Useful Technique To Evaluate Atrial Conduction Time
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalCardiology Journal
dc.contributor.departmentKardiyoloji
dc.identifier.volume19
dc.identifier.issue5
dc.identifier.startpage487
dc.identifier.endpage493
dc.description.indexWoS
dc.description.indexScopus


Files in this item

This item appears in the following Collection(s)

Show simple item record