Basit öğe kaydını göster

dc.contributor.authorErtuğrul, İlker
dc.contributor.authorKaragöz, Tevfik
dc.contributor.authorAykan, Hakan
dc.contributor.authorYıldırım, Işıl
dc.contributor.authorÖzer, Sema
dc.contributor.authorKaragöz, Heves
dc.contributor.authorYılmaz, Mustafa
dc.date.accessioned2019-12-10T11:23:52Z
dc.date.available2019-12-10T11:23:52Z
dc.date.issued2016
dc.identifier.issn2149-2263
dc.identifier.urihttps://doi.org/10.5152/AnatolJCardiol.2015.6589
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5368523/
dc.identifier.urihttp://hdl.handle.net/11655/15603
dc.description.abstractObjective: Although sudden cardiac death is rare in children, an intracardiac defibrillator system is indicated in children with various types of cardiomyopathy, primary electrical diseases, and after surgical repair of congenital heart defects. The use of transvenous defibrillator lead systems is limited in pediatric patients because of a small body size and/or limited vascular access. Subcutaneous array leads combined with an abdominally placed generator can enable implantation. Method: This is a retrospective study of 13 patients who underwent subcutaneous defibrillator implantation between September 2010 and March 2015. The subcutaneous system was preferred because patients were not amenable to transvenous lead placement. Results: The median patient age was 4.1 years, and the median patient weight was 12.1 kg. Diagnoses of patients were long-QT syndrome in 6, aborted cardiac arrest with left ventricular non-compaction in 3, hypertrophic cardiomyopathy with sustained ventricular tachycardia in 3, and arrythmogenic right ventricular cardiomyopathy in 1. Revision of the subcutaneous lead was required in 5 patients 2–26 months after the implantation. Appropriate shocks were observed in three patients. Inappropriate shock and lead fractures were observed in one patient during the follow-up period. The failure of therapy was observed in one patient. There were no perioperative complications and no early or late deaths. Conclusion: Subcutaneous defibrillator systems are safe and effective in pediatric patients when the transvenous method is risky and contraindicated. Because the high growth rate in this population leads to lead failures, a close follow-up of this population is essential. (Anatol J Cardiol 2016; 16: 630-4)
dc.relation.isversionof10.5152/AnatolJCardiol.2015.6589
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleSubcutaneous Defibrillator Implantation in Pediatric Patients
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalAnatolian Journal of Cardiology
dc.contributor.departmentKardiyoloji
dc.identifier.volume16
dc.identifier.issue8
dc.identifier.startpage630
dc.identifier.endpage634
dc.description.indexPubMed
dc.description.indexWoS
dc.description.indexScopus


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster