Basit öğe kaydını göster

dc.contributor.authorArat, A.
dc.contributor.authorCil, B. E.
dc.contributor.authorVargel, I.
dc.contributor.authorTurkbey, B.
dc.contributor.authorCanyigit, M.
dc.contributor.authorPeynircioglu, B.
dc.contributor.authorArat, Y. O.
dc.date.accessioned2019-12-12T06:40:51Z
dc.date.available2019-12-12T06:40:51Z
dc.date.issued2007
dc.identifier.issn0195-6108
dc.identifier.urihttps://doi.org/10.3174/ajnr.A0547
dc.identifier.urihttp://hdl.handle.net/11655/16618
dc.description.abstractBACKGROUND AND PURPOSE: Various techniques and materials have been used for the endovascular treatment of craniofacial high-flow arteriovenous vascular malformations, because their rarity precludes standardization of their treatment. The aim of this retrospective review is to assess Onyx as the primary embolic agent in the treatment of these vascular malformations. MATERIALS AND METHODS: Six patients with arteriovenous fistulas and 3 with arteriovenous malformations (AVMs) of the head and neck region were treated with intra-arterial (IA)/direct percutaneous injections of Onyx. Adjunctive maneuvers used during embolization included external compression of the arterial feeders or venous outflow (6 patients), balloon assist (4 patients), and direct embolization of the draining vein remote to the fistula site (1 patient). n-butyl-2-cyanoacrylate (n-BCA) was used in addition to Onyx for rapid induction of thrombosis in a large venous pouch (1 patient) and for cost containment purposes (I patient). Four patients were treated surgically after the embolization. RESULTS: There were no neurologic complications secondary to the embolization procedure. The arteriovenous shunt was eliminated in all of the fistulous lesions and 2 of the 3 AVMs. The embolization was incomplete in 1 patient with a large AVM who declined further enclovascular or surgical procedures. Untoward events included 2 instances of catheter entrapment (of 9 IA injections), blackish skin discoloration necessitating surgical revision in 1 patient, and difficulty of balloon deflation/wire withdrawal during a balloon-assisted embolization. CONCLUSION: Onyx appears to be a safe and effective liquid emboiic agent for use in the treatment of craniofacial high-flow vascular malformations with distinct advantages and disadvantages compared with n-BCA.
dc.language.isoen
dc.publisherAmer Soc Neuroradiology
dc.relation.isversionof10.3174/ajnr.A0547
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectNeurosciences & Neurology
dc.subjectRadiology, Nuclear Medicine & Medical Imaging
dc.titleEmbolization Of High-Flow Craniofacial Vascular Malformations With Onyx
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalAmerican Journal Of Neuroradiology
dc.contributor.departmentPlastik, Rekonstrüktif ve Estetik Cerrahi
dc.identifier.volume28
dc.identifier.issue7
dc.identifier.startpage1409
dc.identifier.endpage1414
dc.description.indexWoS
dc.description.indexScopus


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster