Ara
Toplam kayıt 12, listelenen: 1-10
3 Boyutlu Baskı Teknolojisi Kullanılarak Hastaya Özgün Konturlarla Oluşturulan Fantom Tasarımı ve Üretimi ile Mikro-Çok Yapraklı Kolimatör Tabanlı Beyin ve Başboyun Yoğunluk Ayarlı Radyoterapi Planlarının Kalite Kontrolü
(Sağlık Bilimleri Enstitüsü, 2017)
SUNEL, S. Quality control of micro-multileaf collimator based brain and head-and-neck intensity modulated radiotherapy plans with patient-specific phantom design and production using 3D printing technology. Hacettepe ...
Modulation of Glucocorticoid Induced Tumor Necrosis Factor Receptor (GITR)-GITR Ligand (GITRL) Interaction in Breast Cancer Cells Under the Control of Ataxia Telangiectasia Mutated (ATM) Promoter
(Kanser Enstitüsü, 2017-07-21)
Treatment response for basal-like breast cancers (BLBC) is limited and this aggressive breast cancer sub-type has poor prognosis and high mortality. Our first aim is to investigate ATM activity in BLBC cell lines with ...
Akciğer Kanserlerinde Stereotaktik Ablatif Beden Radyoterapisinin Toksisite ve Doz - Yanıt İlişkisinin Matematiksel Model ile Görüntü ve Dozimetrik Analizi
(Kanser Enstitüsü, 2017-02-17)
In conventional radiotherapy applications, clinicians and physicist rely upon mathematical dose - response models for applied doses to tumor and periphery healthy tissues. However in stereotactic ablative body radiotherapy ...
Kronik Periodontiti Olan Hastalarda Kanser İnsidansının Değerlendirilmesi
(Kanser Enstitüsü, 2017)
Previous studies have noted possible associations between periodontitis and the risk of various cancers, particularly head and neck cancers, esophageal cancer, lung cancer, pancreatic cancer, breast cancer and non-Hodgkin ...
Cyberknife® X-Sight® Vertebra Takip Sisteminin Vertebra Dışı Lezyonlarda Uygulanabilirliğinin Araştırılması
(Kanser Enstitüsü, 2017-03-25)
One of devices which uses the ablative dose for the Stereotactik body radiation theraphy (SBRT) is CyberKnife® Stereotactic Radiosurgery System. This device, has different tracking system from other devices. This systems ...
Helikal Tomoterapi ile Prostat Işınlamalarında Kritik Organ Dozlarının Cihaz İçi Parametrelere göre Değerlendirilmesi
(Sağlık Bilimleri Enstitüsü, 2017)
The treatment planning of Tomotherapy depends on three device parameters, i.e. field width (FW), pitch (P) and modulation factor (MF). Various treatment plans can be generated with different combinations of these parameters. ...
Vulva Kanserinde Elektron-YART Hibrit Tedavi Modalitesinin Tedavi Planlama Sistemi ve Dozimetrik Yöntemlerle İncelenmesi
(Sağlık Bilimleri Enstitüsü, 2017-02-20)
In recent years, in the treatment of vulvar cancer, intensity modulated radiation therapy (IMRT) have been used instead of 3 dimensional conformal radiotherapy (3DCRT). In this thesis study, 7 patients who were diagnosed ...
Gastrointestinal Sistem Kanserli Hastalarda Mide Doluluğunun Radyoterapiye Etkisi
(Kanser Enstitüsü, 2017)
In the treatment of gastrointestinal system (GIS) cancers, radiotherapy (RT) is frequently applied as three
dimensional conformal RT (3BKRT) or intensity adjusted RT (YART). GIS tumors are very sensitive to
environmental ...
Cyberknife Synchrony® Solunum Takip Sisteminin Polimer Jel Dozimetre ile Üç Boyutlu Performans Analizi
(Kanser Enstitüsü, 2017-02-20)
ŞAHİN, M. C. Three Dimensional Performance Analysis Of Cyberknife Synchrony®
Respiratory Tracking System Using Polymer Gel Dosimeter. Hacettepe University
Institute of Health Sciences, Thesis in Radiotherapy Physics ...
3′End Maturation of Human Telomerase Rna Component (Terc) and Its Effects on Telomere Dynamics
(Sağlık Bilimleri Enstitüsü, 2017-09-15)
Telomerase RNA Component (TERC) is the non-coding RNA template and scaffold of the telomerase holoenzyme. TERC level has been shown to be a limiting factor for telomerase activity, lower levels resulting in telomere diseases ...