• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Enstitüler
  • Kanser Enstitüsü
  • Kanser Enstitüsü Tez Koleksiyonu
  • View Item
  •   DSpace Home
  • Enstitüler
  • Kanser Enstitüsü
  • Kanser Enstitüsü Tez Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Vajinal Kaf Brakiterapi Uygulamaları için Yoğunluk Ayarlı Aplikatör Tasarımı: Dozimetrik Fizibilite Çalışması

View/Open
Tez Dosyası (3.011Mb)
Date
2018
Author
Biltekin, Fatih
xmlui.mirage2.itemSummaryView.MetaData
Show full item record
Abstract
Depending on technological advances in radiotherapy, the use of three-dimensional (3D) treatment planning in brachytherapy (BRT) applications has provided a great advantage in terms of efficacy of treatment in gynecological patients. In this study, it was aimed to design intensity modulated (IM) vaginal cuff applicator which allows IM-BRT applications in gynecologic patients who require vaginal cuff BRT. Applicator, quality assurance phantom and auxiliary fixation devices were modeled in “Sketchup” drawing program and print out from “MakerBot Replicator Z18” 3D printer. The quality control (QC) tests conducted with the aim of testing the clinical use of applicator was carried out in Varian GammaMed Plus iX BRT device and treatment planning simulation processes were performed in BrachyVision treatment planning system (TPS) used in Hacettepe University Department of Radiation Oncology. When the measurement results were analyzed, it was observed that measurements performed in homogenous medium for different measurement conditions were compatible with TPS within 4% differences in point dose measurement. Furthermore, in 2D dosimetry, the number of passing point was found greater than %90 for all measurements using gamma evaluation criteria of 3 mm distance-to-agreement (DTA) and 3% dose difference (DD). In mechanical QC tests it was found that the designed applicator had a positioning accuracy less than 1 mm. In the next stage, prospective studies are planned in an appropriate patient group so that the clinical effectiveness of the applicator can be evaluated.
URI
http://hdl.handle.net/11655/4378
xmlui.mirage2.itemSummaryView.Collections
  • Kanser Enstitüsü Tez Koleksiyonu [56]
xmlui.dri2xhtml.METS-1.0.item-citation
Radyoterapi Fiziği
Hacettepe Üniversitesi Kütüphaneleri
Açık Erişim Birimi
Beytepe Kütüphanesi | Tel: (90 - 312) 297 6585-117 || Sağlık Bilimleri Kütüphanesi | Tel: (90 - 312) 305 1067
Bizi Takip Edebilirsiniz: Facebook | Twitter | Youtube | Instagram
Web sayfası:www.library.hacettepe.edu.tr | E-posta:openaccess@hacettepe.edu.tr
Sayfanın çıktısını almak için lütfen tıklayınız.
Contact Us | Send Feedback



DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV
 

 


DSpace@Hacettepe
huk openaire onayı
by OpenAIRE

About HUAES
Open Access PolicyGuidesSubcriptionsContact

livechat

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherLanguageRightsxmlui.ArtifactBrowser.Navigation.browse_indexFundingxmlui.ArtifactBrowser.Navigation.browse_subtypeThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherLanguageRightsxmlui.ArtifactBrowser.Navigation.browse_indexFundingxmlui.ArtifactBrowser.Navigation.browse_subtype

My Account

LoginRegister

Statistics

View Usage Statistics

DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV