Basit öğe kaydını göster

dc.contributor.authorUzunoglu-Özyürek, Emel
dc.contributor.authorKüçükkaya Eren, Selen
dc.contributor.authorEraslan, Oğuz
dc.contributor.authorBelli, Sema
dc.date.accessioned2021-06-03T08:00:40Z
dc.date.available2021-06-03T08:00:40Z
dc.date.issued2019
dc.identifier.issn2234-7658
dc.identifier.urihttp://dx.doi.org/10.5395/rde.2019.44.e15
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6529799/
dc.identifier.urihttp://hdl.handle.net/11655/24318
dc.description.abstractObjectives The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. 135° angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.
dc.language.isoen
dc.relation.isversionof10.5395/rde.2019.44.e15
dc.rightsAttribution 4.0 United States
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleCritical Evaluation Of Fracture Strength Testing For Endodontically Treated Teeth: A Finite Element Analysis Study
dc.title.alternativeCritical evaluation of fracture strength testing for endodontically treated teeth
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalRestorative Dentistry & Endodontics
dc.contributor.departmentEndodonti
dc.identifier.volume44
dc.identifier.issue2
dc.description.indexPubMed


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

Attribution 4.0 United States
Aksi belirtilmediği sürece bu öğenin lisansı: Attribution 4.0 United States