• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Ana Sayfa
  • Diş Hekimliği Fakültesi
  • Protetik Diş Tedavisi Bölümü
  • Protetik Diş Tedavisi Bölümü Tez Koleksiyonu
  • Öğe Göster
  •   Ana Sayfa
  • Diş Hekimliği Fakültesi
  • Protetik Diş Tedavisi Bölümü
  • Protetik Diş Tedavisi Bölümü Tez Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Farklı Ölçü Yöntemlerinin Maksiller Tam Protezlerin Tutuculuklarına Etkisinin Kalitatif ve Kantitatif Olarak Değerlendirilmesi

Göster/Aç
ilay yörükoğlu uzmanlık tezi..pdf (1.736Mb)
Tarih
2020
Yazar
Yörükoğlu, İlay
Ambargo Süresi
6 ay
Üst veri
Tüm öğe kaydını göster
Özet
YORUKOGLU İ, Effect of impression technique aplied for maxillary complete dentures on retention: Qualitative and quantitative evaluation. Hacettepe University Faculty of Dentistry, Thesis in Prosthodontics, Ankara, 2020. The impression phase is one of the critical steps in the fabrication of a complete denture. Several techniques have been advocated to achive on optimal impression. However, there is no consensus on which are the best impression technique. The purpose of this clinical study was to compare the retention values of maxillary denture bases produced two different impression techniques. Twenty patients with completely edentulous maxillary arches were participated in this study. Maxillary complete dentures were fabricated using two different impression methods. The first method (MS prosthesis) was used a custom tray border moulded with impression compound while second method (M0 prosthesis) was used border moulded simultaneously definitive impression without impression compound. In both techniques definitive impression was made with medium viscosity polyether. The custom-designed testing device was used to measure on qualitative evaluation of denture retention. Each denture base was subjected to a vertical pulling force 3 times by using an advanced digital force gauge. Retention force was measured in Newton(N). 100-mm visual analog scale was used to for quantitative evaluation of denture retention. Denture retention satisfaction was graded by patients. IBM SPSS 23.0 package program was used for statistical analysis. Significantly increased retention was observed for MS prosthesis compared to that M0 prosthesis (p<0.05). No significant difference existed between VAS scores of the MS and M0 prostheses (p>0.05). The results of the present study suggest that the dentures used impression compound will provide better retentive force than the dentures not used impression compound. Patient satisfaction was not affected from used different impression techniques in the short term.
Bağlantı
http://hdl.handle.net/11655/22645
Koleksiyonlar
  • Protetik Diş Tedavisi Bölümü Tez Koleksiyonu [35]
Hacettepe Üniversitesi Kütüphaneleri
Açık Erişim Birimi
Beytepe Kütüphanesi | Tel: (90 - 312) 297 6585-117 || Sağlık Bilimleri Kütüphanesi | Tel: (90 - 312) 305 1067
Bizi Takip Edebilirsiniz: Facebook | Twitter | Youtube | Instagram
Web sayfası:www.library.hacettepe.edu.tr | E-posta:openaccess@hacettepe.edu.tr
Sayfanın çıktısını almak için lütfen tıklayınız.
İletişim | Geri Bildirim



DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV
 

 


DSpace@Hacettepe
huk openaire onayı
by OpenAIRE

Hakkımızda
Açık Erişim PolitikasıVeri Giriş RehberleriÜyeliklerİletişim

livechat

sherpa/romeo

Göz at

Tüm Açık ArşivBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreDile GöreErişim Şekline GöreDizinleme Kaynağına GöreFonlayan Kuruma GöreAlt Türe GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreDile GöreErişim Şekline GöreDizinleme Kaynağına GöreFonlayan Kuruma GöreAlt Türe Göre

Hesabım

GirişKayıt

İstatistikler

Kullanım İstatistiklerini Göster

DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV