Basit öğe kaydını göster

dc.contributor.authorKonukseven, Ozlem
dc.contributor.authorDincol, Ilknur
dc.contributor.authorGenc, G. Aydan
dc.date.accessioned2019-12-19T07:13:27Z
dc.date.available2019-12-19T07:13:27Z
dc.date.issued2012
dc.identifier.issn1308-7649
dc.identifier.urihttps://doi.org/
dc.identifier.urihttp://hdl.handle.net/11655/20995
dc.description.abstractObjective: Some researchers recommend the use of Automated Auditory Brainstem Response as an initial screening test for healthy newborns due to its lower false-positive and referral rates, high specificity, and also its' ability to diagnose auditory neuropathy spectrum disorder combination with Transient Evoked Otoacoustic Emissions test. On the other hand, the test time can be a disadvantage. With technological advancements, a new generation Automated Auditory Brainstem Response has been developed which is faster. The new design of the Automated Auditory Brainstem Response is designed with a coupler that does not contain disposable electrodes is available at an acceptable cost. The aim of this study was comparing the new generation's Automated Auditory Brainstem Response and Transient Evoked Otoacoustic Emissions test by regarding to their test times. The results were then compared with those in previously published literature. Methods: Two hundred and sixty healthy infants were included in the study. The hearing screening of all infants was performed using Transient Evoked Otoacoustic Emissions and Automated Auditory Brainstem Response test devices with new, improved technology. The Ero-ScanTM (Maico, Berlin, Germany) test system was used for the Transient Evoked Otoacoustic Emissions, and the newly designed Maico MB11 BERAphone (Maico-Berlin, Germany) Auditory Brainstem Response screening device with three electrodes in one cap was used for the Automated Auditory Brainstem Response test. Results: Mean age of babies was 60.7+/-51.3 hours, and age range was 4hours-312hours. The test times for the Transient Evoked Otoacoustic Emissions were 13.68+/-9.2s and 14.04+/-9.45, and for the Automated Auditory Brainstem Response, they were 39.15+/-22.2s and 45,25+/-23,9s for the right and left ears respectively. Conclusions: Although the Automated Auditory Brainstem Response test time is statistically longer than the Transient Evoked Otoacoustic Emissions, the amount of time it takes has been significantly shortened by the new technology. This finding enhances the value of the new generation Automated Auditory Brainstem Response technology usage as an initial test for newborn hearing screening.
dc.language.isoen
dc.publisherAves
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectOtorhinolaryngology
dc.titleAutomated Auditory Brainstem Response: A Proposal for an Initial Test For Healthy Newborn Hearing Screening with a Focus on the Test Time
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalJournal Of International Advanced Otology
dc.contributor.departmentOdyoloji
dc.identifier.volume8
dc.identifier.issue3
dc.identifier.startpage419
dc.identifier.endpage425
dc.description.indexWoS


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster