Basit öğe kaydını göster

dc.contributor.authorOzdemir, Ozdemir
dc.contributor.authorTunay, Zuhal Ozen
dc.contributor.authorPetricli, Ikbal Seza
dc.contributor.authorAcar, Damla Erginturk
dc.contributor.authorAcar, Ugur
dc.contributor.authorErol, Muhammet Kazim
dc.date.accessioned2019-12-12T06:47:19Z
dc.date.available2019-12-12T06:47:19Z
dc.date.issued2014
dc.identifier.issn0004-2749
dc.identifier.urihttps://doi.org/10.5935/0004-2749.20140058
dc.identifier.urihttp://hdl.handle.net/11655/17041
dc.description.abstractPurpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP) were allocated to Group 1 (n= 138), while those without ROP were allocated to Group 2 (n= 236). All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male). The mean gestational age at birth was 30.7 +/- 2.7 weeks (range 25-36 weeks), the mean birth weight was 1,514 +/- 533.3 g (range 750-1,970 g), and the mean postmenstrual age at examination was 40.0 +/- 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p < 0.05). There were no significant differences in horizontal corneal diameter, central corneal thickness, and axial length between the two groups (p > 0.05). Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.
dc.language.isoen
dc.publisherConsel Brasil Oftalmologia
dc.relation.isversionof10.5935/0004-2749.20140058
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectOphthalmology
dc.titleAnalysis of the Horizontal Corneal Diameter, Central Corneal Thickness, and Axial Length in Premature Infants
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.relation.journalArquivos Brasileiros De Oftalmologia
dc.contributor.departmentGöz Hastalıkları
dc.identifier.volume77
dc.identifier.issue4
dc.identifier.startpage225
dc.identifier.endpage227
dc.description.indexWoS
dc.description.indexScopus


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster